Why Motor rated in kW instead of kVA?

Asked by Last Modified  

Follow 2
Answer

Please enter your answer

Teacher

There are two type of losses in a transformer; 1. Copper Losses 2. Iron Losses or Core Losses or Insulation Losses Copper losses ( I²R)depends on Current which passing through transformer winding while Iron Losses or Core Losses or Insulation Losses depends on Voltage. So the Cu Losses depend...
read more
There are two type of losses in a transformer; 1. Copper Losses 2. Iron Losses or Core Losses or Insulation Losses Copper losses ( I²R)depends on Current which passing through transformer winding while Iron Losses or Core Losses or Insulation Losses depends on Voltage. So the Cu Losses depend on the rating current of the load so the load type will determine the powerfactor P.F , Thats why the rating of Transformer in kVA,Not in kW. Designer doesn’t know the actual consumer power factor while manufacturing transformers and generators i.e. the P.F (Power factor) of Transformer and Generator/Alternator depends on the nature of connected load such as resistive load, capacitive load, and inductive load as Motors, etc. But Motor has fixed Power factor, i.e. motor has defined power factor and the rating has been mentioned in KW on Motor nameplate data table. That’s why we are rated Motor in kW or HP (kilowatts/ Horsepower) instead of kVA. In addition, Motor is a device which converts Electrical power into Mechanical power. In this case, the load is not electrical, but mechanical (Motor’s Output) and we take into the account only active power which has to be converted into mechanical load. Moreover, the motor power factor does not depend on the load and it works on any P.F because of its design. read less
Comments

B.Tech(EC/EE/IN),Math(IX,X,XI,XII std.),Physics(IX,X,XI,XII std.) CBSE/ICSE/IB.

motor has defined power factor and the rating has been mentioned in KW . That's why we are rated Motor in kW or HP (kilowatts/ Horsepower) instead of kVA. also, Motor is a device which converts Electrical power into Mechanical power
Comments

Maths and physics teacher till engineering level

motor has defined power factor and the rating has been mentioned in KW . That's why we are rated Motor in kW or HP (kilowatts/ Horsepower) instead of kVA. also, Motor is a device which converts Electrical power into Mechanical power
Comments

Researcher

Motor has a fixed Power factor, i.e. motor has a defined power factor and the rating has been mentioned in KW...
Comments

Electrical Engineering

KW means involves pf. KVA means rated(true) power.. Not only motor alone has kw rating, all the load have kw..
Comments

Quality teaching with intense care

Motor converts electrical energy into mechanical energy. Only the active power flows through motor shaft. Also the power factor of the motor is independent of load power factor unlike alternators where power factor of load affects the overall power factor. Thus alternators may need to supply or consume...
read more
Motor converts electrical energy into mechanical energy. Only the active power flows through motor shaft. Also the power factor of the motor is independent of load power factor unlike alternators where power factor of load affects the overall power factor. Thus alternators may need to supply or consume reactive power depending on load power factor. However in case of motor it has to supply the active power only as only mechanical load can be connected to motor shaft. Hence the rating is in kW or W or H.P. and not in KVA. read less
Comments

math magician

because of power factor
Comments

Motor power factor are fixed and the motor converted to electrical to mechanical so that the motor rating in kw(kilo watt)
Comments

View 6 more Answers

Related Questions

What are advantages of taking GATE coaching?
Through GATE there are many jobs
Meenakshisundarams
1 0
5
Why we can’t store AC in Batteries instead of DC?
If we consider charging mechanism of electro-chemical cell or battery,it is continuous process of injecting electrons on negative side(-Ve) plate and protons positive side(+Ve) plate. When we see an AC...
Sreedevi
0 0
6
Hi How can I check my GATE application status?
GATE ME 2016 online classes from 17th March 2015. For more details, please feel free to contact.
Mithun
How many points in IELTS required for Canada?
To secure a Canadian student visa, you must have a minimum IELTS score of 6.0. with no band less than 5.5.
Prince
0 0
5
no need to carry calculator....on screen calculator wil bi available in sysytem
No they have intimated the candidates to carry a non-programmable calculator with them
Muralikrishna

Now ask question in any of the 1000+ Categories, and get Answers from Tutors and Trainers on UrbanPro.com

Ask a Question

Related Lessons

Magnetism MCQ
1. One of the following is not a source of magnetostatic fields: a. A dc current in a wire. b. A permanent magnet. c. An accelerated charge. d. An electric field Linearly changing with time. e. A...

How To Prepare For GATE Exam?
Well, many students struggles to qulify and/or to get high rank in GATE exam. Many people drop their dreams halfway due to negative thoughts or due to pressure. But how to overcome our shortcommings? How...

Textile water waste treatment
extile wastewater purification: The textile industry is rated as one of the most polluting and chemically intensive industrial sectors (Uzal, 2015). -Chemicals like acids, alkalis, colours, high BOD/COD...

Fighting your Fear
Hello buddies. I am Prof. Sneh Pragya. I want to talk about the most major issue we face in life. "FEAR" this word has done lot of holes n our personality. we fear what if i fall. I will broke my leg. what...

Career Opportunities for B.tech -instrumentation Fresher
What after completion of B.Tech-Instrumentation??? A person who has completed his B.tech in Instrumentation Engineering has the following opportunities: 1. As Instrumentation Engineer in Instrumentation...

Looking for GATE Coaching ?

Learn from the Best Tutors on UrbanPro

Are you a Tutor or Training Institute?

Join UrbanPro Today to find students near you